Spectrophotometric Methods for the Determination of Etoricoxib in Pharmaceutical Formulations

Chaple DR and Bhusari KP*

Sharad Pawar College of Pharmacy, Wanadongri, Higana Road, Nagpur-441 110 Maharashtra, India.

*Corresponding Author E-mail: d.chaple@rediffmail.com

 

ABSTRACT

Simple UV and first derivative spectrophotometric methods have been developed for the determination of etoricoxib in tablet dosage form. In simple UV method, spectrum of etoricoxib in 0.1 N HCl showed absorbance maximum at 271.6 nm, where as in first derivative spectrum it shows maxima at 265.2 nm and minima at 301.6 nm. Beer’s law is obeyed over the concentration range 1-25µg/ml. The developed methods have been successfully applied for the determination of etoricoxib in tablet dosage form. The results obtained by the proposed methods were validated by recovery studies.

 

KEYWORDS: Etoricoxib, derivative spectrophotometry. 

 


INTRODUCTION:

Etoricoxib1 is a new non-steroidal anti-inflammatory drug (NSAID) with selective COX-2 inhibitory activity. Chemically it is 5-chloro-2-(6-methylpyridin-3-yl)-3-(4-methylsulfonylphenyl) pyridine. It is commonly used for osteoarthritis, rheumatoid arthritis, primary dysmenorrhoea, postoperative dental pain and acute gout. This drug is not official in any pharmacopoeia. Literature survey reveals a few reported spectrophotometric2,3, HPLC4-7 and HPTLC8 methods for the estimation of etoricoxib in bulk drugs and pharmaceutical formulation, as well as from urine and plasma.

 

MATERIALS AND METHODS:

Chemicals and Reagents:

Pure etoricoxib was obtained from Cadila Healthcare Ltd., Raigad. The tablets (referred as T1 and T2) were purchased from a local pharmacy (The label claim for both T1 and T2 contained 60 mg of etoricoxib). All chemicals used were of analytical grade.

 

Instrument:

All absorbance measurements were made on a Shimadzu UV 1601 UV-Visible double beam spectrophotometer with 1 cm matched quartz cell.

 

Standard drug solution:     

About 50 mg of etoricoxib was weighed accurately and dissolved in 50 ml methanol to get concentration 1mg/ml. 10 ml of aliquots further diluted to 100 ml with 0.1 N HCl to get a concentration of 100 µg/ml.

 

Assay procedure:

Method I- Simple UV spectrophotometric method:

The standard solution of etoricoxib (10 μg/ml) in 0.1 N HCl was scanned in the entire UV range to determine λmax of the drug. The λmax of etoricoxib was found to be 271.6 nm. Aliquots of the working standard solution of etoricoxib (0.1-2.5 ml,       10-250μg) were transferred in a series of 10 ml volumetric flask and diluted up to the mark with 0.1 N HCl. The absorbances of resulting solutions were measured at 271.6 nm and calibration curve was plotted.

 

Method II- First derivative spectrophotometric method:

Aliquots of the working standard solution of etoricoxib (0.1-2.5 ml, 10-250 μg) were transferred into a series of 10 ml volumetric flasks and volume were made up to mark with 0.1 N HCl. The first derivative curves were obtained which showed maxima at 265.2 nm and minima at 301.6 nm (fig.1). The calibration curve was prepared by plotting the absorbance difference between maxima and minima (i.e. amplitude) verses concentration.

 

The Optical characteristics such absorption maxima, Beer’s law limit, molar extinction coefficient and regression equation of both methods are presented in Table 1.

 

Analysis of etoricoxib in tablet dosage form:

Twenty tablets were weighed and finely powdered. An accurately weighed quantity of powder equivalent to 50 mg of etoricoxib was transferred in 100 ml beaker. Using mechanical stirrer the powder was completely disintegrated in methanol. The resulting mixture was filtered through a whatman filter paper No. 40 and diluted up to 50 ml with methanol and the same procedure was applied as described under the procedure for the pure sample. The results of analysis are given in Table 2.

 

 


Table 1: Optical and Regression characteristics of Etoricoxib in different method

Parameters

 Simple UV method

First derivative Method

Absorption maxima

271.6

265.2

Absorption minima

-

243.8

Beer’s law limit (μg/ml)

1-25 µg/ml

1-25 µg/ml

Molar absorptivity   (l/mol.cm)

1.6908 x 104

0.1485 x 104

Correlation coefficient (r2)

0.9981

0.9993

Regression equation

 Slope (a)

 Intercept (b)­­­

 

0.05508

0.0281

 

0.0041

0.0005

 

Table 2: Results of Analysis of Etoricoxib in Tablet

Formulation

Label claim    (mg/tab)

Method

% of Label Claim* ± S.D

% Recovery* ± S.D

T1

60

I

 99.98 ± 0.072

99.62 ± 0.019

 

 

II

100.00 ± 0.063

99.73 ± 0.143

T2

60

I

100.00 ± 0.076

99.73 ± 0.253

 

 

II

100.10 ± 0.135

99.73 ± 0.213

* Mean of five determinations, Method I- Simple UV method, and Method II- First derivative method.

 


Fig. 1. First derivative spectrum of etoricoxib.

 

RESULTS AND DISCUSSION:

In order to validate an efficient method for the analysis of drug in pharmaceutical formulations, preliminary tests were performed with objective to select adequate and optimum conditions. Parameters such as absorption maxima, absorption minima, selection of solvent and concentration of the standard solutions were studied.

 

The calibration curves showed linearity over a concentration range from 1.0 to 25.0 μg/ml for simple UV method and first derivative method. The correlation coefficients obtained with linear regression of curve were above 0.9980. Accuracy was determined by recovery study of etoricoxib, known amount of etoricoxib was added into the preanalysed sample and subjected them to the proposed spectrophotometric methods. The results of recovery study are shown in Table 2.

 

A sharp peak is observed in first derivative as compare to second derivative spectrum. The good amplitude and linearity were observed over the given concentration range. The results of analysis of tablet dosage form by both methods, t-calculated values and f-calculated values were less than the corresponding statistical values indicating no significant difference in means and variance of results obtained by either of the proposed methods. Both the proposed methods are simple, sensitive and accurate for the determination of Etoricoxib in bulk drugs and tablet dosage forms.

 

ACKNOWLEDGEMENTS:

The authors are thankful to M/s Cadila Healthcare Ltd., Raigad for providing gift sample of drug.

 

REFERENCES:

1.       Cochrane DJ, Jarvis B and Keating GM. Adis new drug profile: etoricoxib. Drug.   2002; 62: 2637.

2.       Singh RM, Kumar Y, Sharma DK, Mathur SC, Singh GN, Ansari TA and Jamil S. Spectrophotometric method for the estimation of etoricoxib formulation. Indian Drugs. 2005; 42: 535.

3.       Suhagia BN, Patel HM, Shah SA, Rathod IS and Marolia BP. Spectrophotometric    estimation of etoricoxib in bulk and dosage forms. Indian  J.  Pharm. Sci. 2005; 67: 634.

4.       Ramakrishna NVS, Vishwottam KN, Wishu S and Koteshwara M. Validated liquid    chromatographic ultraviolet method for the quantitation of etoricoxib in human plasma using liquid–liquid extraction. J. of Chromatography B. 2005; 816: 215.

5.       Bräutigam L, Jens U. Nefflen JU and Geisslinger G. Determination of etoricoxib in human plasma by liquid chromatography–tandem mass spectrometry with electrospray ionization. J. of Chromatography B. 2003; 788: 309.

6.       Ansari TA, Jamil S, Singh RM, Mathur SC, Shivraj and Singh GN. Determination of etoricoxib in bulk drug and its dosage forms by RP HPLC. Indian Drugs. 2005; 42: 56.

7.       Mandal U, Rajan DS, Bose A, Gowda KV, Ghosh A and Pal T. K. Development and validation of an HPLC method for analysis of etoricoxib in human plasma. Indian J. Pharm. Sci. 2006; 68: 485.

8.       Shah NJ, Shah SJ, Patel DM and Patel NM. Development and validation of   HPTLC method for the estimation of etoricoxib. Indian J. Pharm. Sci. 2006; 68: 788.

 

 

 

Received on 16.02.2009       Modified on 22.06.2009

Accepted on 28.07.2009      © RJPT All right reserved

Research J. Pharm. and Tech.2 (3): July-Sept. 2009,;Page 597-598